20th Anniversary Customer Appreciation Event
Book Today Call Now Online Shop Get a Quote

Fair Lawn NJ Furnace and Air Conditioning Repair Installation Service

Book Today
Google Rating
4.8
Based on 317 reviews
js_loader
Climate Plus, LLC
5.0
Based on 259 reviews

There’s No Better Choice In Fair Lawn, NJ For Expert HVAC Service

Since 1990, New Jerseyites living in Fair Lawn have known there is only one phone call they need to make to handle all of their heating and cooling needs – Climate Plus. Our technicians are the best in the business, our tools are state-of-the-art and our commitment to quality work is unmatched. Add all that up, and the choice is clear. Whether you’re looking for HVAC repair, HVAC installation, HVAC maintenance or improved indoor air quality, we’ve got your back, front, sides, top and bottom.

Explore the links below to check out reviews from your neighbors in Fair Lawn, NJ and the surrounding areas to see what they have to say about our service – after all, our clients are always our best cheerleaders. Then when your furnace is on the fritz, or you need a new central AC, you’ll know there’s only one name you need to remember – Climate Plus.

Recent Jobs and Reviews in Fair Lawn, NJ

Rated 5.0 out of 5 stars based on 3 customer reviews

Our Local Reviews by City

Job Locations and Reviews

Fair Lawn, NJ - Arrived on site for driving cleaning. Customer led me to the event outside on the left side of the house. Use portable cable compressor to clean out the dryer vent from the outside. Ask customer to run the dryer inside. Fed hose down the vent and waited for the compressor to build up pressure. Took out a great amount of that was restriction the dryer vent. Went inside the event about 4 to 5 times with the hose to ensure cleanliness of the dryer vent. After cleaning dryer vent picked up all the link off the ground, cleaning up the best to the ability.
Gianna M.
Gianna M. Checked in
Arrived on site for driving cleaning. Customer led me to the event outside on the left side of the house. Use portable cable compressor to clean out the dryer vent from the outside. Ask customer to run the dryer inside. Fed hose down the vent and waited for the compressor to build up pressure. Took out a great amount of that was restriction the dryer vent. Went inside the event about 4 to 5 times with the hose to ensure cleanliness of the dryer vent. After cleaning dryer vent picked up all the link off the ground, cleaning up the best to the ability.
Fair Lawn, NJ 07410
Fair Lawn, NJ - All right on site for maintenance. Customer led me to the basement where the air handlers located. Customer turned on the unit and saw the unit fully functional. Took out the old filtering replacing with a filter that was applied on site. Open up the evaporator code to check out the mirroring device in the condition of the evaporator coil. The main device is a piston and evaporator cause rain good condition. Also inserted two condensate treatment pills inside the condensate tray. I made sure that the water pump of the air handler was fully functional. Went outside pull the disconnect of the condenser to work on it safely and took out the top. Wash down the unit with chemical and water. Put the condenser back together and turn on the condenser and it turned on normally. Check the pressures with the field pieces. High pressure was a little low but it was 69 outside.
Gianna M.
Gianna M. Checked in
All right on site for maintenance. Customer led me to the basement where the air handlers located. Customer turned on the unit and saw the unit fully functional. Took out the old filtering replacing with a filter that was applied on site. Open up the evaporator code to check out the mirroring device in the condition of the evaporator coil. The main device is a piston and evaporator cause rain good condition. Also inserted two condensate treatment pills inside the condensate tray. I made sure that the water pump of the air handler was fully functional. Went outside pull the disconnect of the condenser to work on it safely and took out the top. Wash down the unit with chemical and water. Put the condenser back together and turn on the condenser and it turned on normally. Check the pressures with the field pieces. High pressure was a little low but it was 69 outside.
Fair Lawn, NJ 07410
Jack B.
Jack B. Checked in
Arrived onsite for no cooling call. Condenser fan motor failed. Homeowner looking to replace system. Installed condenser fan motor. System still running hot. Misters had been added to the condenser that are helping
Fair Lawn, NJ 07410
Fair Lawn, NJ - Arrived onsite for no cooling service call. Customer explained the breaker keeps tripping. Performed diagnostic. Removed compressor from the circuit and fan worked. Tested compressor wires for resistance measure a jumping ohm up to 300. Measures resistance to ground. Took top off and measure resistance on compressor leads. Again had high resistance measurement between leads. Measured resistance to ground in all 3 terminals. The compressor is confirmed grounded. Left plug off compressor. Returned disconnect in off position. Proving for replacement is being worked up.
Jack B.
Jack B. Checked in
Arrived onsite for no cooling service call. Customer explained the breaker keeps tripping. Performed diagnostic. Removed compressor from the circuit and fan worked. Tested compressor wires for resistance measure a jumping ohm up to 300. Measures resistance to ground. Took top off and measure resistance on compressor leads. Again had high resistance measurement between leads. Measured resistance to ground in all 3 terminals. The compressor is confirmed grounded. Left plug off compressor. Returned disconnect in off position. Proving for replacement is being worked up.
Fair Lawn, NJ 07410
Jack B.
Jack B. Checked in
Arrived on site for no Cooling. Customer turned on the unit when I arrived, the condenser outside was humming loudly. Sound like the the compressor was working but the fan was not spinning. Unplug the disconnect and open up the wiring for the condenser. Check for voltage and amps everything was fine checked out the capacitor that was pretty rusted up on the top but it was fine. Every component was working good except for the fan. Notice that the fan has a thermal protection, rang up the hose and tried calling it down for about 5 minutes with water.
Fair Lawn, NJ 07410
Fair Lawn, NJ - Arrived on site for no Cooling. Customer turned on the unit when I arrived, the condenser outside was humming loudly. Sound like the the compressor was working but the fan was not spinning. Unplug the disconnect and open up the wiring for the condenser. Check for voltage and amps everything was fine checked out the capacitor that was pretty rusted up on the top but it was fine. Every component was working good except for the fan. Notice that the fan has a thermal protection, rang up the hose and tried calling it down for about 5 minutes with water. At the cooling down the condenser turned on the connector by plugging in the disconnect and the unit turned on very loudly. Check for pressures and pressures were pretty low super heat was higher than 50 and what temperature difference inside the house Peak at four degrees difference.
Gianna M.
Gianna M. Checked in
Arrived on site for no Cooling. Customer turned on the unit when I arrived, the condenser outside was humming loudly. Sound like the the compressor was working but the fan was not spinning. Unplug the disconnect and open up the wiring for the condenser. Check for voltage and amps everything was fine checked out the capacitor that was pretty rusted up on the top but it was fine. Every component was working good except for the fan. Notice that the fan has a thermal protection, rang up the hose and tried calling it down for about 5 minutes with water. At the cooling down the condenser turned on the connector by plugging in the disconnect and the unit turned on very loudly. Check for pressures and pressures were pretty low super heat was higher than 50 and what temperature difference inside the house Peak at four degrees difference.
Fair Lawn, NJ 07410
Jack B.
Jack B. Checked in
UV Light Air Purification Installation: Installed a UV-C germicidal light system inside the HVAC air handler to neutralize airborne pathogens. Connected the unit to the blower control circuit, ensuring it operated only during air circulation, and verified UV output for indoor air quality improvement.
Fair Lawn, NJ 07410
Fair Lawn, NJ - Arrived onsite for ac maintenance on 1 system. Homeowner mentioned noise from indoor blower fan. Could not recreate the noise. System worked well while there. . Checked all electrical. Chemically Cleaned outside coil. measured pressures for 410a at 120/245psi with 5 degree sub cooling with outside temperature at 81 degrees. Measured temperature drop at 17 degrees. Cleaned out condensate line. Removed 20x20x1 filter located in air handler. Installed 2 -14x28x1 filters in filter grill provided by the homeowner System running as it should.
Jack B.
Jack B. Checked in
Arrived onsite for ac maintenance on 1 system. Homeowner mentioned noise from indoor blower fan. Could not recreate the noise. System worked well while there. . Checked all electrical. Chemically Cleaned outside coil. measured pressures for 410a at 120/245psi with 5 degree sub cooling with outside temperature at 81 degrees. Measured temperature drop at 17 degrees. Cleaned out condensate line. Removed 20x20x1 filter located in air handler. Installed 2 -14x28x1 filters in filter grill provided by the homeowner System running as it should.
Fair Lawn, NJ 07410
Fair Lawn, NJ - Arrived on site for maintenance.
No one was in the building.
Someone left unit running, started outside.
Washed down condenser.
Checked pressures of condenser,
Gianna M.
Gianna M. Checked in
Arrived on site for maintenance. No one was in the building. Someone left unit running, started outside. Washed down condenser. Checked pressures of condenser,
Fair Lawn, NJ 07410
Fair Lawn, NJ - Arrived onsite for no cooling call. Performed diagnostic on the system. Found a fault in the voltage enhancement system. Inspected motors and they seem to be in working order. Performed gold repair for the voltage enhancement system. System running as it should. Measured 30 degree temperature drop. Did not observe strange noises. Pressure within line of manufacturer’s settings. Confirmed filter is in good shape.
Jack B.
Jack B. Checked in
Arrived onsite for no cooling call. Performed diagnostic on the system. Found a fault in the voltage enhancement system. Inspected motors and they seem to be in working order. Performed gold repair for the voltage enhancement system. System running as it should. Measured 30 degree temperature drop. Did not observe strange noises. Pressure within line of manufacturer’s settings. Confirmed filter is in good shape.
Fair Lawn, NJ 07410
Jack B.
Jack B. Checked in
customer experiencing unit slowing down and not cooling well it is around 15 years old and so is the furnace. He is interested in replacing, well aware that may be a possibility.
Fair Lawn, NJ 07410
Joseph C.
Joseph C. Checked in
Received a call at the AC system was not operating, upon arrival I found that the unit was running but low on refrigerant. It is an older R22 system and I do not recommend leak testing at this time. Added 3 lb of R22 refrigerant and the unit is now operating and cooling properly.
Fair Lawn, NJ 07410
Fair Lawn, NJ - Arrived on site for no cooling call.
Condenser fan was running.
Air handler was running
Compressor was off.
Checked/tested capacitor.
Capacitor was dead.
Replaced capacitor.
Compressor and condenser was fully operational.
Updated customer. Customer acknowledged and signed off.
Gianna M.
Gianna M. Checked in
Arrived on site for no cooling call. Condenser fan was running. Air handler was running Compressor was off. Checked/tested capacitor. Capacitor was dead. Replaced capacitor. Compressor and condenser was fully operational. Updated customer. Customer acknowledged and signed off.
Fair Lawn, NJ 07410
Gianna M.
Gianna M. Checked in
Heating System Repair: Diagnosed a cracked heat exchanger that posed a safety hazard. Removed and installed a new exchanger, ensuring proper combustion and restoring safe, efficient heat output.
Fair Lawn, NJ 07410
Fair Lawn, NJ - UV bulb replacement.
Gianna M.
Gianna M. Checked in
UV bulb replacement.
Fair Lawn, NJ 07410
Fair Lawn, NJ - Seasonal maintenance for (1) split system up to 5 ton cooling capacity, either roof or ground mounted
Includes replacing of standard fiberglass air filter (pleated higher performance filters can be added at an additional cost) , includes replacing blower belt (if applicable), grease or oil bearings, chemically clean the condensing unit, clean the condensate drain line, check operation of all safety devices, check operation of operating controls, check all motors, compressor and refrigerant charge, visual inspection of the duct system. With a Comfort Club service you will also receive the added benefits of a 10% discount on repairs and diagnostic fees, service within 48 hours of placing the call and a water heater flush
Gianna M.
Gianna M. Checked in
Seasonal maintenance for (1) split system up to 5 ton cooling capacity, either roof or ground mounted Includes replacing of standard fiberglass air filter (pleated higher performance filters can be added at an additional cost) , includes replacing blower belt (if applicable), grease or oil bearings, chemically clean the condensing unit, clean the condensate drain line, check operation of all safety devices, check operation of operating controls, check all motors, compressor and refrigerant charge, visual inspection of the duct system. With a Comfort Club service you will also receive the added benefits of a 10% discount on repairs and diagnostic fees, service within 48 hours of placing the call and a water heater flush
Fair Lawn, NJ 07410
Fair Lawn, NJ - Arrived onsite for ac maintenance on 1 units. Asked customer to turn AC on to confirm operation. Checked all electrical. Chemically Cleaned outside unit, measured pressures for 410a at 125/265psi with 10 degree sub cooling with outside temperature at 72 degrees. Measured temperature drop at 20 degrees. Cleaned condensate line. changed 20x30x1 filter. Performed efficiency test utilizing MeasureQuick. System running as it should.
Gianna M.
Gianna M. Checked in
Arrived onsite for ac maintenance on 1 units. Asked customer to turn AC on to confirm operation. Checked all electrical. Chemically Cleaned outside unit, measured pressures for 410a at 125/265psi with 10 degree sub cooling with outside temperature at 72 degrees. Measured temperature drop at 20 degrees. Cleaned condensate line. changed 20x30x1 filter. Performed efficiency test utilizing MeasureQuick. System running as it should.
Fair Lawn, NJ 07410
Gerard E.
Gerard E. Checked in
HVAC Repair: Upgraded an outdated thermostat with a modern programmable unit, allowing for better temperature scheduling and improved energy management.
Fair Lawn, NJ 07410
Fair Lawn, NJ - Arrived onsite for ac maintenance on 1 units. Asked customer to turn AC on to confirm operation. Checked all electrical. Chemically Cleaned outside unit, removed debris, cleared drainage holes. Observed a rusting in the outside condenser, measured pressures for R22 at 48/120psi with 17 degree sub cooling with outside temperature at 60degrees. Observed the suction line icing up. Cleaned evaporator coil and blew out condensate line. Observed significant rusting on the evaporator coil. Observed more icing on the inside coil. Recommend upgrading the system based on age and condition of the system.
Jack B.
Jack B. Checked in
Arrived onsite for ac maintenance on 1 units. Asked customer to turn AC on to confirm operation. Checked all electrical. Chemically Cleaned outside unit, removed debris, cleared drainage holes. Observed a rusting in the outside condenser, measured pressures for R22 at 48/120psi with 17 degree sub cooling with outside temperature at 60degrees. Observed the suction line icing up. Cleaned evaporator coil and blew out condensate line. Observed significant rusting on the evaporator coil. Observed more icing on the inside coil. Recommend upgrading the system based on age and condition of the system.
Fair Lawn, NJ 07410
Fair Lawn, NJ - Arrived onsite for ac maintenance on 1 units. Asked customer to turn AC on to confirm operation. Homeowner will changed filter in ceiling. No longer using 213 filter media. Checked all electrical. Chemically Cleaned outside unit removed debris and VMware’s drainage holes. measured pressures for 410a at 111/206psi with 10degree sub cooling with outside temperature at 60 degrees. Measured temperature drop at 18.5 degrees. Cleaned evaporator coil and cleared condensate line. System running as it should.
Jack B.
Jack B. Checked in
Arrived onsite for ac maintenance on 1 units. Asked customer to turn AC on to confirm operation. Homeowner will changed filter in ceiling. No longer using 213 filter media. Checked all electrical. Chemically Cleaned outside unit removed debris and VMware’s drainage holes. measured pressures for 410a at 111/206psi with 10degree sub cooling with outside temperature at 60 degrees. Measured temperature drop at 18.5 degrees. Cleaned evaporator coil and cleared condensate line. System running as it should.
Fair Lawn, NJ 07410
Fair Lawn, NJ - Arrived onsite for ac maintenance on 1 system. Turn AC on to confirm operation. Checked all electrical. Removed condenser top and clear debris. Chemically Cleaned outside coils and cleared drain holes, measured pressures for R407c at 47/101psi with 1.4 degree sub cooling with outside temperature at 48 degrees. Measured temperature drop at 21 degrees. Cleaned evaporator coil and condensate line. Changed 213 media filter provided by Climate Plus. System running as it should.
Jack B.
Jack B. Checked in
Arrived onsite for ac maintenance on 1 system. Turn AC on to confirm operation. Checked all electrical. Removed condenser top and clear debris. Chemically Cleaned outside coils and cleared drain holes, measured pressures for R407c at 47/101psi with 1.4 degree sub cooling with outside temperature at 48 degrees. Measured temperature drop at 21 degrees. Cleaned evaporator coil and condensate line. Changed 213 media filter provided by Climate Plus. System running as it should.
Fair Lawn, NJ 07410
Steven M.
Steven M. Checked in
HVAC Repairs: Upon inspecting a client’s HVAC system, I discovered damaged insulation on the electrical wiring, posing both safety and performance concerns. I promptly replaced the compromised insulation to restore safe and efficient system operation.
Fair Lawn, NJ 07410
Gerard E.
Gerard E. Checked in
Removed old boiler installed new crown velocity boiler. Installed four new zones plus an indirect tank was existing. Piped in indirect tank the proper way on auxiliary. Installed magna clean, expansion tank, spiral vent, Purge setup, with three separate circulator pumps. Pumps also included four zone valves. Everything is isolated and operating at this time. Ran 2-in PVC outside vented proper distances from Windows and doors.
Fair Lawn, NJ 07410
Fair Lawn, NJ - Arrived onsite for heating maintenance 2 gas fired furnaces 1 in basement and 1 in the attic.

Attic Furnace System: Turn heat on and confirmed operation. Changed 14x24x1 filter provided by customer.
Brushed and Wiped down furnance blower cabinet and gas burners. Burners fired and are in good working order. No visual impingement detected. Checked electrical. Cleaned the flame sensor.. Measure temperature rise at 42 degrees. Performed Combustion Test. System is operating as it should. Discuss replacement of basement system as it is near 20 years and has used over 95% of its life expectancy. Homeowner would like to wait a couple more years.
Jack B.
Jack B. Checked in
Arrived onsite for heating maintenance 2 gas fired furnaces 1 in basement and 1 in the attic. Attic Furnace System: Turn heat on and confirmed operation. Changed 14x24x1 filter provided by customer. Brushed and Wiped down furnance blower cabinet and gas burners. Burners fired and are in good working order. No visual impingement detected. Checked electrical. Cleaned the flame sensor.. Measure temperature rise at 42 degrees. Performed Combustion Test. System is operating as it should. Discuss replacement of basement system as it is near 20 years and has used over 95% of its life expectancy. Homeowner would like to wait a couple more years.
Fair Lawn, NJ 07410
Fair Lawn, NJ - Arrived onsite for maintenance on 4 systems. Performed inspection of the performance, mechanical, and safety systems. Started in suite 202. Confirmed operation of all systems. Cleaned washable filters on 3 mini split cassettes. Changed 20x20x1 ceiling filter. Measured temperature drop of 20 degrees on the big unit. 23 degrees in the small unit. 17 degrees on the ceiling split system.
Jack B.
Jack B. Checked in
Arrived onsite for maintenance on 4 systems. Performed inspection of the performance, mechanical, and safety systems. Started in suite 202. Confirmed operation of all systems. Cleaned washable filters on 3 mini split cassettes. Changed 20x20x1 ceiling filter. Measured temperature drop of 20 degrees on the big unit. 23 degrees in the small unit. 17 degrees on the ceiling split system.
Fair Lawn, NJ 07410
Review
Joe and the crew did a fantastic job replacing and upgrading our heating system. The crew were extra careful by laying down drop cloths and corner protectors. They communicated clearly and cleaned up completely afterwards. Highly recommended.
Mark Richards - Fair Lawn, NJ 07410
Response from Climate Plus, LLC:

Mark, thank you for the fantastic review! We're glad to hear that Joe and the crew took great care in cleaning your ducts while keeping your home protected. Clear communication and thorough cleanup are always a priority for us, and we appreciate you noticing! If you ever need anything in the future, we're here to help. Thanks again for recommending Climate Plus! -The Climate Plus Team

Review
Always friendly, professional, and courteous.
Fr Kevin PJ Coffey - Fair Lawn, NJ 07410
Response from Climate Plus, LLC:

Thank you, Kevin, for your kind words! We're so glad to hear that you find our team friendly, professional, and courteous. It’s always a pleasure serving you, and we look forward to helping with any of your HVAC needs in the future. -The Climate Plus Team

Review
He was great!!! Thank you!!!
Yvonne Curtin - Fair Lawn, NJ 07410
Response from Climate Plus, LLC:

Thank you for the wonderful feedback, Yvonne! We're thrilled to hear you had a great experience during your heating maintenance. It was our pleasure to ensure your Payne High Efficiency furnace is working properly, and we're glad we could address the thermostat issue. If you need any further assistance or that Spring AC maintenance, we're here to help! – The Climate Plus Team

Review
Excellent service
Brian - Fair Lawn, NJ 07410
Response from Climate Plus, LLC:

Thank you so much for the 5-star review, Brian! We're so glad you received excellent service from Climate Plus. If you ever need assistance again, we’re here for all your HVAC needs!

Review
Mr. Cascone was really great, explained everything well.
Brian Ives - Fair Lawn, NJ 07410
Response from Climate Plus, LLC:

Thank you, Brian, for your kind words! We're delighted to hear that Mr. Cascone provided great service and explained everything thoroughly during the job in Fair Lawn. At Climate Plus, we aim to deliver exceptional service and clear communication on every project. If you ever need HVAC services in Fair Lawn or have any questions, we're here to help! Best regards, The Climate Plus Team

Review
Servicemen on time and always friendly and efficient. While it's never pleasant to spend $$ on a repair, the situation was fully explained to me and I also understand that nothing is inexpensive nowadays. I would recommend your service.
Satisfied Customer - Fair Lawn, NJ 07410
Response from Climate Plus, LLC:

We're glad to hear that our servicemen were on time, friendly, and efficient. We understand that repairs can be costly, but we're pleased that everything was explained clearly to you. Your recommendation means a lot to us. Thank You, Joseph

Review
Excellent communication as well as service.
Alan - Fair Lawn, NJ 07410
Trusted Quality & Service
Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Contact and Service Location...
*
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at (973) 838-3200 .

Back Next