Trust The Comfort Of Your Oak Ridge, NJ Home To The Best In HVAC Service

If you live in Northern New Jersey, then you already know that for decades Climate Plus has been the go-to HVAC service provider. Whether it's HVAC maintenance or AC repair, Climate Plus has always had our Oak Ridge customers' best interests at heart. Not only that, but we also specialize in installation, oil to gas conversions on furnaces and heat pumps when needed. If you're looking for ways to improve your indoor air quality, we've got you covered there too! We offer a variety of tools including UV lights, humidifiers and dehumidifiers, and the best air filters around so you can keep your home nice and comfortable all day long. So don't delay; next time you need HVAC services or AC repair call  (973) 838-3200  so you can rest easy knowing the air inside your home is as clean and cozy as it's ever been!

How much does AC repair cost near Oak Ridge?

The cost of AC repair can vary depending on the specific issue and the geographic location. Minor repairs like a refrigerant recharge or replacing a capacitor can cost between $100 to $500. More significant repairs, like fixing a compressor or replacing a coil, can cost $1,000 to $2,500 or more. The cost of repairs may also depend on the age and condition of the AC unit. It's important to obtain a written estimate from a licensed HVAC contractor before any work is done to ensure transparency and accuracy of the cost.

Why did my home AC unit stop working all of a sudden near Oak Ridge?

There can be a variety of reasons why a home AC unit stops working all of a sudden. Some common causes include a tripped circuit breaker, a dirty air filter, a malfunctioning thermostat, a faulty capacitor, a refrigerant leak, or a frozen evaporator coil. It's also possible that there is a problem with the compressor or the fan motor. It's best to have a licensed HVAC contractor diagnose the issue to determine the cause and provide the appropriate repair. Regular maintenance can also help prevent sudden breakdowns of AC units.

How often do AC units need to be serviced near Oak Ridge?

AC units should be serviced at least once a year, preferably before the start of the cooling season. This regular maintenance can help to ensure that the unit is running efficiently and effectively, and can also help to identify any potential problems before they become major issues. During a maintenance visit, a licensed HVAC contractor will typically inspect the unit, clean the coils and filters, lubricate moving parts, check refrigerant levels, and test the electrical components. Regular servicing can also extend the life of the AC unit and improve indoor air quality.

What is the most expensive part to fix on a furnace in Oak Ridge, NJ?

The heat exchanger is often the most expensive part to fix on a furnace. It's a critical component responsible for transferring heat, and if it develops cracks or malfunctions, it poses safety risks, including carbon monoxide leaks. Repairing or replacing a heat exchanger is a labor-intensive process requiring professional expertise. Costs can vary based on furnace type, brand, and the complexity of the repair. Generally, the price range can be anywhere from a few hundred to over a thousand dollars. Due to safety concerns and the technical nature of the task, addressing heat exchanger issues should be left to licensed HVAC professionals for proper assessment and resolution.

What are the most common furnace repairs in Oak Ridge, NJ?

Common furnace repairs in Oak Ridge, NJ, include issues with the ignition system, such as a faulty pilot light or ignition control problems. Thermostat malfunctions, dirty filters, and problems with the blower motor are also frequent. Additionally, wear and tear on components like the heat exchanger or gas valve may require attention. Regular maintenance can help prevent some of these issues, and consulting with local HVAC professionals is recommended for accurate diagnosis and effective repairs.

Hear It From Our Greatest Cheerleaders - Our Customers!

Our customer reviews speak for themselves - Climate Plus takes the cake when it comes to quality HVAC services in New Jersey. With over hundreds of customer recommendations going back to our earliest days, our commitment to honest, dependable work is unmatched. Check out all of our customer reviews below and find out why we're a degree above the rest. When you're ready to get serious about your HVAC services, why not go with a team that's tried and true? Give us a call at Climate Plus and experience honest service with a side of Jersey humor!

Recent Jobs and Reviews in Oak Ridge, NJ

Our Local Reviews by City

Job Locations and Reviews

Conducted on-site evaluation at rental property for complete AC system replacement. Documented existing electrical panel configuration showing dedicated AC circuit breaker and assessed basement mechanical room housing current furnace and HVAC infrastructure. Provided comprehensive replacement estimate for new single-zone air conditioning system installation.
Conducted on-site evaluation at rental property for complete AC system replacement. Documented existing electrical panel configuration showing dedicated AC circuit breaker and assessed basement mechanical room housing current furnace and HVAC infrastructure. Provided comprehensive replacement estimate for new single-zone air conditioning system installation.
Joseph C.
Joseph C. Checked in
Conducted on-site evaluation at rental property for complete AC system replacement. Documented existing electrical panel configuration showing dedicated AC circuit breaker and assessed basement mechanical room housing current furnace and HVAC infrastructure. Provided comprehensive replacement estimate for new single-zone air conditioning system installation.
Oak Ridge, NJ 07438
Responded to no cooling call with reported leak. Upon inspection in attic, found air handler with accessible internal components including blower motor assembly and filter. Performed diagnostic testing using multimeter to assess electrical connections and system functionality. Inspected refrigerant lines, ductwork connections, and condensate drainage system. Located source of leak and completed necessary repairs to restore proper operation. Verified system cooling capacity and confirmed all components functioning within normal parameters before departure.
Responded to no cooling call with reported leak. Upon inspection in attic, found air handler with accessible internal components including blower motor assembly and filter. Performed diagnostic testing using multimeter to assess electrical connections and system functionality. Inspected refrigerant lines, ductwork connections, and condensate drainage system. Located source of leak and completed necessary repairs to restore proper operation. Verified system cooling capacity and confirmed all components functioning within normal parameters before departure.
Gerard E.
Gerard E. Checked in
Responded to no cooling call with reported leak. Upon inspection in attic, found air handler with accessible internal components including blower motor assembly and filter. Performed diagnostic testing using multimeter to assess electrical connections and system functionality. Inspected refrigerant lines, ductwork connections, and condensate drainage system. Located source of leak and completed necessary repairs to restore proper operation. Verified system cooling capacity and confirmed all components functioning within normal parameters before departure.
Oak Ridge, NJ 07438
# No AC - Wiring Issue Resolution

Responded to no cooling complaint and diagnosed faulty wiring connections on the HVAC control board. Upon inspection, identified loose and improperly terminated wire connections at the terminal block and relay circuit that were preventing the system from operating. Removed and reinstalled affected wire connections, ensuring proper seating in all terminal blocks and connector housings. Verified all relay switches, including the HJR-4102-L-12VDC relay and DELTA relay, were functioning correctly. Tested all wire terminations for secure contact and proper voltage delivery to control components. Restored power to the system and confirmed proper operation of all circuits. System tested successfully with all functions operating as designed.
# No AC - Wiring Issue Resolution

Responded to no cooling complaint and diagnosed faulty wiring connections on the HVAC control board. Upon inspection, identified loose and improperly terminated wire connections at the terminal block and relay circuit that were preventing the system from operating. Removed and reinstalled affected wire connections, ensuring proper seating in all terminal blocks and connector housings. Verified all relay switches, including the HJR-4102-L-12VDC relay and DELTA relay, were functioning correctly. Tested all wire terminations for secure contact and proper voltage delivery to control components. Restored power to the system and confirmed proper operation of all circuits. System tested successfully with all functions operating as designed.
Joseph C.
Joseph C. Checked in
# No AC - Wiring Issue Resolution Responded to no cooling complaint and diagnosed faulty wiring connections on the HVAC control board. Upon inspection, identified loose and improperly terminated wire connections at the terminal block and relay circuit that were preventing the system from operating. Removed and reinstalled affected wire connections, ensuring proper seating in all terminal blocks and connector housings. Verified all relay switches, including the HJR-4102-L-12VDC relay and DELTA relay, were functioning correctly. Tested all wire terminations for secure contact and proper voltage delivery to control components. Restored power to the system and confirmed proper operation of all circuits. System tested successfully with all functions operating as designed.
Oak Ridge, NJ 07438
Responded to no cooling call where HVAC unit became unresponsive after customer cycled the breaker. Upon arrival, found that previous attempts to resolve the issue included fuse and transformer replacement, but unit remained non-functional. Performed comprehensive electrical diagnostics using clamp meter to test voltage and amperage at various points in the system. Inspected control board, wiring connections, and safety circuits. Identified failed door interlock switch preventing unit operation. Removed defective latch mechanism and installed replacement part. Verified proper electrical continuity, tested all safety switches, and confirmed system startup. Unit now operating normally with thermostat communication restored.
Responded to no cooling call where HVAC unit became unresponsive after customer cycled the breaker. Upon arrival, found that previous attempts to resolve the issue included fuse and transformer replacement, but unit remained non-functional. Performed comprehensive electrical diagnostics using clamp meter to test voltage and amperage at various points in the system. Inspected control board, wiring connections, and safety circuits. Identified failed door interlock switch preventing unit operation. Removed defective latch mechanism and installed replacement part. Verified proper electrical continuity, tested all safety switches, and confirmed system startup. Unit now operating normally with thermostat communication restored.
Joseph C.
Joseph C. Checked in
Responded to no cooling call where HVAC unit became unresponsive after customer cycled the breaker. Upon arrival, found that previous attempts to resolve the issue included fuse and transformer replacement, but unit remained non-functional. Performed comprehensive electrical diagnostics using clamp meter to test voltage and amperage at various points in the system. Inspected control board, wiring connections, and safety circuits. Identified failed door interlock switch preventing unit operation. Removed defective latch mechanism and installed replacement part. Verified proper electrical continuity, tested all safety switches, and confirmed system startup. Unit now operating normally with thermostat communication restored.
Oak Ridge, NJ 07438
Conducted comprehensive site assessment for HVAC system upgrade involving replacement of existing air conditioning unit and installation of second unit to establish dual-zone cooling configuration. Evaluated current outdoor condenser unit, electrical service capacity at 200-amp main panel, and available infrastructure including existing conduit routing and disconnect location. Documented equipment specifications, electrical requirements, and installation parameters necessary for preparing detailed estimate for complete two-zone system implementation.
Conducted comprehensive site assessment for HVAC system upgrade involving replacement of existing air conditioning unit and installation of second unit to establish dual-zone cooling configuration. Evaluated current outdoor condenser unit, electrical service capacity at 200-amp main panel, and available infrastructure including existing conduit routing and disconnect location. Documented equipment specifications, electrical requirements, and installation parameters necessary for preparing detailed estimate for complete two-zone system implementation.
Joseph C.
Joseph C. Checked in
Conducted comprehensive site assessment for HVAC system upgrade involving replacement of existing air conditioning unit and installation of second unit to establish dual-zone cooling configuration. Evaluated current outdoor condenser unit, electrical service capacity at 200-amp main panel, and available infrastructure including existing conduit routing and disconnect location. Documented equipment specifications, electrical requirements, and installation parameters necessary for preparing detailed estimate for complete two-zone system implementation.
Oak Ridge, NJ 07438
Completed AC system estimate in attic space. Documented existing green air handler unit positioned on wooden platform with exposed ductwork and insulation. Photographed equipment dimensions, duct configurations, and current installation conditions including flexible ductwork and fiberglass insulation placement for estimate preparation.
Completed AC system estimate in attic space. Documented existing green air handler unit positioned on wooden platform with exposed ductwork and insulation. Photographed equipment dimensions, duct configurations, and current installation conditions including flexible ductwork and fiberglass insulation placement for estimate preparation.
Joseph C.
Joseph C. Checked in
Completed AC system estimate in attic space. Documented existing green air handler unit positioned on wooden platform with exposed ductwork and insulation. Photographed equipment dimensions, duct configurations, and current installation conditions including flexible ductwork and fiberglass insulation placement for estimate preparation.
Oak Ridge, NJ 07438
Performed inspection and assessment of Rheem air conditioning evaporator coil and drain pan system located in attic space. Upon examination, discovered severe biological contamination in the metal drain pan, with extensive mold and algae growth covering the pan surface due to prolonged condensate accumulation. Documented existing conditions through photography, including the contaminated drain pan, evaporator coil assembly, condensate drainage piping with PVC and copper components, and surrounding attic infrastructure. Provided estimate for drain pan replacement to address contamination issue and prevent potential water damage or system failure.
Performed inspection and assessment of Rheem air conditioning evaporator coil and drain pan system located in attic space. Upon examination, discovered severe biological contamination in the metal drain pan, with extensive mold and algae growth covering the pan surface due to prolonged condensate accumulation. Documented existing conditions through photography, including the contaminated drain pan, evaporator coil assembly, condensate drainage piping with PVC and copper components, and surrounding attic infrastructure. Provided estimate for drain pan replacement to address contamination issue and prevent potential water damage or system failure.
Joseph C.
Joseph C. Checked in
Performed inspection and assessment of Rheem air conditioning evaporator coil and drain pan system located in attic space. Upon examination, discovered severe biological contamination in the metal drain pan, with extensive mold and algae growth covering the pan surface due to prolonged condensate accumulation. Documented existing conditions through photography, including the contaminated drain pan, evaporator coil assembly, condensate drainage piping with PVC and copper components, and surrounding attic infrastructure. Provided estimate for drain pan replacement to address contamination issue and prevent potential water damage or system failure.
Oak Ridge, NJ 07438
Completed seasonal maintenance on CPFP 2 air conditioning system. Inspected electrical components including dual run capacitor and wiring connections, verified all terminals secure and properly connected. Performed system diagnostics using digital manifold gauges, recording operating pressures and temperatures to confirm unit operating within manufacturer specifications.
Completed seasonal maintenance on CPFP 2 air conditioning system. Inspected electrical components including dual run capacitor and wiring connections, verified all terminals secure and properly connected. Performed system diagnostics using digital manifold gauges, recording operating pressures and temperatures to confirm unit operating within manufacturer specifications.
Cody F.
Cody F. Checked in
Completed seasonal maintenance on CPFP 2 air conditioning system. Inspected electrical components including dual run capacitor and wiring connections, verified all terminals secure and properly connected. Performed system diagnostics using digital manifold gauges, recording operating pressures and temperatures to confirm unit operating within manufacturer specifications.
Oak Ridge, NJ 07438
Responded to no cooling call and found ducted air conditioning system with frozen evaporator coil upon arrival. Inspected attic-mounted air handler and confirmed ice buildup on coil and refrigerant lines. Examined outdoor condensing unit and associated refrigerant piping, noting oxidation on copper lines and weathered insulation. Shut down system to allow complete defrost cycle of evaporator coil. Checked airflow at air handler and found restricted airflow due to insufficient return air or dirty filter causing coil temperature to drop below freezing point. Verified refrigerant line insulation integrity on both suction and liquid lines. Allowed adequate time for ice to melt completely before further diagnostics. System requires follow-up service to address underlying cause of freeze condition, which may include checking refrigerant charge levels, verifying proper airflow across evaporator coil, inspecting blower motor operation, and replacing air filter if restricted.
Responded to no cooling call and found ducted air conditioning system with frozen evaporator coil upon arrival. Inspected attic-mounted air handler and confirmed ice buildup on coil and refrigerant lines. Examined outdoor condensing unit and associated refrigerant piping, noting oxidation on copper lines and weathered insulation. Shut down system to allow complete defrost cycle of evaporator coil. Checked airflow at air handler and found restricted airflow due to insufficient return air or dirty filter causing coil temperature to drop below freezing point. Verified refrigerant line insulation integrity on both suction and liquid lines. Allowed adequate time for ice to melt completely before further diagnostics. System requires follow-up service to address underlying cause of freeze condition, which may include checking refrigerant charge levels, verifying proper airflow across evaporator coil, inspecting blower motor operation, and replacing air filter if restricted.
Gerard E.
Gerard E. Checked in
Responded to no cooling call and found ducted air conditioning system with frozen evaporator coil upon arrival. Inspected attic-mounted air handler and confirmed ice buildup on coil and refrigerant lines. Examined outdoor condensing unit and associated refrigerant piping, noting oxidation on copper lines and weathered insulation. Shut down system to allow complete defrost cycle of evaporator coil. Checked airflow at air handler and found restricted airflow due to insufficient return air or dirty filter causing coil temperature to drop below freezing point. Verified refrigerant line insulation integrity on both suction and liquid lines. Allowed adequate time for ice to melt completely before further diagnostics. System requires follow-up service to address underlying cause of freeze condition, which may include checking refrigerant charge levels, verifying proper airflow across evaporator coil, inspecting blower motor operation, and replacing air filter if restricted.
Oak Ridge, NJ 07438
Oak Ridge, NJ - Conducted comprehensive AC system estimate at residential property. Performed visual inspection and documentation of existing attic-mounted air handler unit, associated flexible ductwork distribution system, and condensate drainage assembly. Photographed current HVAC installation including equipment specifications, duct connections, and PVC drain line configuration to provide accurate replacement or repair recommendations.
Joseph C.
Joseph C. Checked in
Conducted comprehensive AC system estimate at residential property. Performed visual inspection and documentation of existing attic-mounted air handler unit, associated flexible ductwork distribution system, and condensate drainage assembly. Photographed current HVAC installation including equipment specifications, duct connections, and PVC drain line configuration to provide accurate replacement or repair recommendations.
Oak Ridge, NJ 07438
Responded to no cooling call and performed diagnostic evaluation of HVAC system. Upon arrival, accessed unit interior compartment and conducted comprehensive inspection of electrical components, refrigerant lines, and control systems. Verified proper connections at control board terminal blocks and examined capacitors for functionality. Checked thermostat operation on dual Budderfly digital controls, noting temperature differentials between set points and actual readings. Utilized diagnostic testing equipment to assess system performance parameters and documented equipment condition through photographic record for service file.
Responded to no cooling call and performed diagnostic evaluation of HVAC system. Upon arrival, accessed unit interior compartment and conducted comprehensive inspection of electrical components, refrigerant lines, and control systems. Verified proper connections at control board terminal blocks and examined capacitors for functionality. Checked thermostat operation on dual Budderfly digital controls, noting temperature differentials between set points and actual readings. Utilized diagnostic testing equipment to assess system performance parameters and documented equipment condition through photographic record for service file.
Joseph C.
Joseph C. Checked in
Responded to no cooling call and performed diagnostic evaluation of HVAC system. Upon arrival, accessed unit interior compartment and conducted comprehensive inspection of electrical components, refrigerant lines, and control systems. Verified proper connections at control board terminal blocks and examined capacitors for functionality. Checked thermostat operation on dual Budderfly digital controls, noting temperature differentials between set points and actual readings. Utilized diagnostic testing equipment to assess system performance parameters and documented equipment condition through photographic record for service file.
Oak Ridge, NJ 07438
Oak Ridge, NJ - Completed installation of new HVAC unit. Installed evaporator coil assembly with refrigerant lines, pressure gauges, filter drier, and associated components within metal cabinet housing. System properly mounted, connected, and prepared for operation with all refrigeration circuit components secured and accessible for future service.
Gerard E.
Gerard E. Checked in
Completed installation of new HVAC unit. Installed evaporator coil assembly with refrigerant lines, pressure gauges, filter drier, and associated components within metal cabinet housing. System properly mounted, connected, and prepared for operation with all refrigeration circuit components secured and accessible for future service.
Oak Ridge, NJ 07438
Completed installation of Coleman air handler unit in attic space, positioning equipment on wooden platform and securing all mounting connections. Connected refrigerant lines with protective covering, installed PVC condensate drain system with safety pan and valve controls, and verified proper integration of ductwork with reflective insulation barriers per manufacturer specifications.
Completed installation of Coleman air handler unit in attic space, positioning equipment on wooden platform and securing all mounting connections. Connected refrigerant lines with protective covering, installed PVC condensate drain system with safety pan and valve controls, and verified proper integration of ductwork with reflective insulation barriers per manufacturer specifications.
Jack B.
Jack B. Checked in
Completed installation of Coleman air handler unit in attic space, positioning equipment on wooden platform and securing all mounting connections. Connected refrigerant lines with protective covering, installed PVC condensate drain system with safety pan and valve controls, and verified proper integration of ductwork with reflective insulation barriers per manufacturer specifications.
Oak Ridge, NJ 07438
Oak Ridge, NJ - Responded to no cooling call on central air conditioning unit following power surge event. Diagnosed system failure caused by electrical damage from power surge, which required new electrical wiring installation prior to HVAC assessment. Performed complete diagnostic evaluation of AC system to determine extent of damage and identify any additional components affected by the electrical event.
Joseph C.
Joseph C. Checked in
Responded to no cooling call on central air conditioning unit following power surge event. Diagnosed system failure caused by electrical damage from power surge, which required new electrical wiring installation prior to HVAC assessment. Performed complete diagnostic evaluation of AC system to determine extent of damage and identify any additional components affected by the electrical event.
Oak Ridge, NJ 07438
Completed full system replacement due to condenser damage from falling ice. Removed existing R410A system and installed new Goodman condenser unit with R454b refrigerant on existing concrete pad. Replaced indoor evaporator coil mounted on furnace to ensure compliance with current code requirements for refrigerant leak detection system. Connected electrical service, refrigerant lines, and condensate drainage. System tested and operational.
Completed full system replacement due to condenser damage from falling ice. Removed existing R410A system and installed new Goodman condenser unit with R454b refrigerant on existing concrete pad. Replaced indoor evaporator coil mounted on furnace to ensure compliance with current code requirements for refrigerant leak detection system. Connected electrical service, refrigerant lines, and condensate drainage. System tested and operational.
Cody F.
Cody F. Checked in
Completed full system replacement due to condenser damage from falling ice. Removed existing R410A system and installed new Goodman condenser unit with R454b refrigerant on existing concrete pad. Replaced indoor evaporator coil mounted on furnace to ensure compliance with current code requirements for refrigerant leak detection system. Connected electrical service, refrigerant lines, and condensate drainage. System tested and operational.
Oak Ridge, NJ 07438
Conducted comprehensive ductwork assessment in basement area with exposed ceiling joists and existing HVAC infrastructure. Evaluated current flexible ductwork configuration, documented existing mechanical equipment including water heater and heating unit, and photographed space constraints around storage areas and shelving units to determine optimal routing for proposed ductwork installation.
Conducted comprehensive ductwork assessment in basement area with exposed ceiling joists and existing HVAC infrastructure. Evaluated current flexible ductwork configuration, documented existing mechanical equipment including water heater and heating unit, and photographed space constraints around storage areas and shelving units to determine optimal routing for proposed ductwork installation.
Joseph C.
Joseph C. Checked in
Conducted comprehensive ductwork assessment in basement area with exposed ceiling joists and existing HVAC infrastructure. Evaluated current flexible ductwork configuration, documented existing mechanical equipment including water heater and heating unit, and photographed space constraints around storage areas and shelving units to determine optimal routing for proposed ductwork installation.
Oak Ridge, NJ 07438
Oak Ridge, NJ - Performed complete system recovery and refrigerant evacuation. Accessed supply plenum to visually inspect evaporator coil, then brushed and chemically cleaned coil surfaces. Verified metering device operation and conducted nitrogen pressure leak test to ensure system integrity. Evacuated system to 500 microns, recharged with fresh refrigerant to manufacturer specifications, and successfully started system with confirmed proper operation.
Gerard E.
Gerard E. Checked in
Performed complete system recovery and refrigerant evacuation. Accessed supply plenum to visually inspect evaporator coil, then brushed and chemically cleaned coil surfaces. Verified metering device operation and conducted nitrogen pressure leak test to ensure system integrity. Evacuated system to 500 microns, recharged with fresh refrigerant to manufacturer specifications, and successfully started system with confirmed proper operation.
Oak Ridge, NJ 07438
Responded to no hot water and no heat call. Upon arrival, inspected wall-mounted boiler system and domestic hot water heater serving the residence. Evaluated extensive copper piping manifold configuration, expansion tank, circulator pump, and zone valves throughout the heating distribution system. Diagnosed system failure affecting both space heating and domestic hot water production. Performed necessary repairs to restore boiler operation and verified proper function of all heating zones. Tested domestic hot water heater connections and confirmed adequate hot water delivery. Cycled system through complete heating cycle, verified circulator pump operation, checked expansion tank pressure, and confirmed all zone valves responding appropriately. System restored to full operational status with both heat and hot water functioning normally throughout the residence.
Responded to no hot water and no heat call. Upon arrival, inspected wall-mounted boiler system and domestic hot water heater serving the residence. Evaluated extensive copper piping manifold configuration, expansion tank, circulator pump, and zone valves throughout the heating distribution system. Diagnosed system failure affecting both space heating and domestic hot water production. Performed necessary repairs to restore boiler operation and verified proper function of all heating zones. Tested domestic hot water heater connections and confirmed adequate hot water delivery. Cycled system through complete heating cycle, verified circulator pump operation, checked expansion tank pressure, and confirmed all zone valves responding appropriately. System restored to full operational status with both heat and hot water functioning normally throughout the residence.
Gerard E.
Gerard E. Checked in
Responded to no hot water and no heat call. Upon arrival, inspected wall-mounted boiler system and domestic hot water heater serving the residence. Evaluated extensive copper piping manifold configuration, expansion tank, circulator pump, and zone valves throughout the heating distribution system. Diagnosed system failure affecting both space heating and domestic hot water production. Performed necessary repairs to restore boiler operation and verified proper function of all heating zones. Tested domestic hot water heater connections and confirmed adequate hot water delivery. Cycled system through complete heating cycle, verified circulator pump operation, checked expansion tank pressure, and confirmed all zone valves responding appropriately. System restored to full operational status with both heat and hot water functioning normally throughout the residence.
Oak Ridge, NJ 07438
Oak Ridge, NJ - Performed the maintenance for the hot air furnace, replaced the filter and cycled the system. Performed a full measured big scan on the operation of the system, it confirmed that all combustion readings, voltages, and readings, and safety controls are operating and working correctly. The furnace is operating properly at this time.
Jack B.
Jack B. Checked in
Performed the maintenance for the hot air furnace, replaced the filter and cycled the system. Performed a full measured big scan on the operation of the system, it confirmed that all combustion readings, voltages, and readings, and safety controls are operating and working correctly. The furnace is operating properly at this time.
Oak Ridge, NJ 07438
Steven M.
Steven M. Checked in
Summertime HVAC Tune-Up: Completed a seasonal maintenance service that included detailed coil cleaning, refrigerant pressure check, drain line flush, filter replacement, and digital thermostat calibration. This proactive service increased system efficiency and helped prevent mid-summer breakdowns.
Oak Ridge, NJ 07438
Steven M.
Steven M. Checked in
Tankless Water Heater Installation: Mounted and connected a high-efficiency tankless water heater to the home’s water and gas supply. Verified proper venting and performed system testing to ensure consistent hot water delivery and reduced energy consumption.
Oak Ridge, NJ 07438
Joseph C.
Joseph C. Checked in
Air Duct Sealing: Sealed and insulated existing ductwork to eliminate air leaks, enhance system performance, and maintain consistent indoor temperatures throughout the home.
Oak Ridge, NJ 07438
Allison O.
Allison O. Checked in
HVAC System Repair Service: Responding to a service call for an HVAC unit that was failing to cool a home, I conducted a thorough system evaluation. I uncovered electrical grounding issues that posed both safety and reliability concerns. After correcting these issues, I restored safe and efficient system functionality.
Oak Ridge, NJ 07438
Oak Ridge, NJ - Arrived onsite for ac maintenance on 2 systems. Opened outside condenser units. Removed all debris. Chemically cleaned the coils. Cleaned the drains. Inspected all electrical. Cleaned electric panel. Changed all filters. 2-20x25x4 . For the Coleman condenser in front of the building, no power to the unit from the Generac box. Inspected the box found the voltage control system engaged but not voltage passing to the condenser. Recommend contacting an electrician. Found Honeywell thermostat with low battery alert. Replaced with new batteries and still observed low battery indicator and alert. Possibly a fault in the thermostat.
Jack B.
Jack B. Checked in
Arrived onsite for ac maintenance on 2 systems. Opened outside condenser units. Removed all debris. Chemically cleaned the coils. Cleaned the drains. Inspected all electrical. Cleaned electric panel. Changed all filters. 2-20x25x4 . For the Coleman condenser in front of the building, no power to the unit from the Generac box. Inspected the box found the voltage control system engaged but not voltage passing to the condenser. Recommend contacting an electrician. Found Honeywell thermostat with low battery alert. Replaced with new batteries and still observed low battery indicator and alert. Possibly a fault in the thermostat.
Oak Ridge, NJ 07438
Jack B.
Jack B. Checked in
AC Repair: Arriving at a client’s home for AC system issues, I conducted a thorough circuit board assessment. Repairing faulty components and addressing potential short circuits restored stable, uninterrupted cooling performance.